- 1. [Amps] Glass Power Tube rebuilders (score: 1)
- Author: "John T. M. Lyles" <jtml@lanl.gov>
- Date: Fri, 4 Jun 2004 12:13:50 -0600
- The problem that I have experienced with rebuilders is that they haven't been able to get the glass in sizes that used to be common, i.e., a blank in the size of a 3-1000Z diameter, from Germany (Sho
- /archives//html/Amps/2004-06/msg00022.html (7,053 bytes)
- 2. Re: [Amps] Glass Power Tube rebuilders (score: 1)
- Author: "Ian White, G3SEK" <G3SEK@ifwtech.co.uk>
- Date: Sat, 5 Jun 2004 09:27:47 +0100
- John T. M. Lyles wrote: The problem that I have experienced with rebuilders is that they haven't been able to get the glass in sizes that used to be common, i.e., a blank in the size of a 3-1000Z dia
- /archives//html/Amps/2004-06/msg00024.html (8,634 bytes)
- 3. Re: [Amps] Glass Power Tube rebuilders (score: 1)
- Author: R.Measures <r@somis.org>
- Date: Sat, 5 Jun 2004 15:46:23 -0700
- On Jun 5, 2004, at 1:27 AM, Ian White, G3SEK wrote: John T. M. Lyles wrote: The problem that I have experienced with rebuilders is that they haven't been able to get the glass in sizes that used to b
- /archives//html/Amps/2004-06/msg00031.html (9,502 bytes)
- 4. Re: [Amps] Glass Power Tube rebuilders (score: 1)
- Author: R.Measures <r@somis.org>
- Date: Sun, 6 Jun 2004 02:26:05 -0700
- On Jun 5, 2004, at 11:56 PM, Ian White wrote: Hello R. Measures Hello, Mr. White On Jun 5, 2004, at 1:27 AM, Ian White, G3SEK wrote: John T. M. Lyles wrote: The problem that I have experienced with r
- /archives//html/Amps/2004-06/msg00033.html (10,518 bytes)
- 5. Re: [Amps] Glass Power Tube rebuilders (score: 1)
- Author: "K7RDX" <k7rdx@earthlink.net>
- Date: Sun, 6 Jun 2004 07:10:34 -0700
- If this method to restore emission is to work, how do you keep the filament from burning up and the acetylene gas from igniting while in a non-vacuum filament on time? What`s the rest of the story Mr
- /archives//html/Amps/2004-06/msg00035.html (10,996 bytes)
- 6. RE: [Amps] Glass Power Tube rebuilders (score: 1)
- Author: "G0RUZ Conrad" <conrad@g0ruz.net>
- Date: Sun, 6 Jun 2004 17:25:23 +0100
- Rich Measurew wrote...... Is that actually a rebuild? That just sounds like restoring the 'chemistry'. Surely a rebuild requires the total removal of the 'innards'. I can't for the life of me see how
- /archives//html/Amps/2004-06/msg00036.html (8,445 bytes)
- 7. Re: [Amps] Glass Power Tube rebuilders (score: 1)
- Author: "Ian White, G3SEK" <G3SEK@ifwtech.co.uk>
- Date: Sun, 6 Jun 2004 18:33:32 +0100
- R. Measures wrote: John was clearly talking about other problems where there *was* a need to cut the tube apart. It's probably easier to melt a hole than to cut the glass. That's "metalwork thinkin
- /archives//html/Amps/2004-06/msg00037.html (9,337 bytes)
- 8. Re: [Amps] Glass Power Tube rebuilders (score: 1)
- Author: R.Measures <r@somis.org>
- Date: Mon, 7 Jun 2004 03:09:04 -0700
- On Jun 6, 2004, at 9:25 AM, G0RUZ Conrad wrote: Rich Measurew wrote...... To restore the emission of thoriated tungsten filament, glass envelope tube, the vacuum pump connecting tube is opened, acety
- /archives//html/Amps/2004-06/msg00041.html (9,794 bytes)
- 9. Re: [Amps] Glass Power Tube rebuilders (score: 1)
- Author: R.Measures <r@somis.org>
- Date: Mon, 7 Jun 2004 03:33:54 -0700
- On Jun 6, 2004, at 10:33 AM, Ian White, G3SEK wrote: R. Measures wrote: John was clearly talking about other problems where there *was* a need to cut the tube apart. It's probably easier to melt a
- /archives//html/Amps/2004-06/msg00042.html (10,798 bytes)
- 10. RE: [Amps] Glass Power Tube rebuilders (score: 1)
- Author: "Skram, Helge (MED)" <helge.skram@med.ge.com>
- Date: Mon, 7 Jun 2004 13:31:12 +0200
- The problem that I have experienced with rebuilders is that they haven't been able to get the glass in sizes that used to be common, i.e., a blank in the size of a 3-1000Z diameter, from Germany (Sho
- /archives//html/Amps/2004-06/msg00043.html (9,675 bytes)
- 11. [Amps] Glass Power Tube rebuilders (score: 1)
- Author: Will Matney <craxd1@ezwv.com>
- Date: Mon, 07 Jun 2004 13:00:37 -0400
- "If this method to restore emission is to work, how do you keep the filament from burning up and the acetylene gas from igniting while in a non-vacuum filament on time? What`s the rest of the story M
- /archives//html/Amps/2004-06/msg00046.html (9,316 bytes)
This search system is powered by
Namazu