- 1. [Amps] Dentron MLA2500B on 10 meters (score: 1)
- Author: samvideo@escape.ca (Ron Samchuk)
- Date: Thu, 17 Oct 2002 08:35:59 -0500
- Hi everyone: This is my first time on 'Amps' reflector. I recently = purchased a Dentron MLA2500B which seems to be in good condition. At = present, it does not operate on 10 meters, but it seems by
- /archives//html/Amps/2002-10/msg00192.html (6,958 bytes)
- 2. [Amps] Dentron MLA2500B on 10 meters (score: 1)
- Author: jhurry@austin.rr.com (Dudley Hurry)
- Date: Thu, 17 Oct 2002 10:56:44 -0500
- Ron, Move the stop on the bandswitch and there is also a filter in the output that will need to be removed.. It's mounted on a small board after the TR relay... Thanks and 73's, Dudley WA5QPZ jhurry@
- /archives//html/Amps/2002-10/msg00193.html (7,512 bytes)
- 3. [Amps] Dentron MLA2500B on 10 meters (score: 1)
- Author: robinda@nortelnetworks.com (David Robinson)
- Date: Thu, 17 Oct 2002 11:14:45 -0500
- On my amp the 24MHz LP filter that needs to be removed is on the input to the amplifier ie before the tubes Dave g4fre Hi everyone: This is my first time on 'Amps' reflector. I recently = purchased a