Search String: Display: Description: Sort:

Results:

References: [ +subject:/^(?:^\s*(re|sv|fwd|fw)[\[\]\d]*[:>-]+\s*)*\[Amps\]\s+Band\s+switching\s*$/: 3 ]

Total 3 documents matching your query.

1. [Amps] Band switching (score: 1)
Author: "hermans" <on4kj@skynet.be>
Date: Sat, 11 Mar 2006 12:20:39 -0000
Hello All, Might be a stupid question...... To avoid using old ledex to swich the tank coil, why one doesn't use relays or PIN diode ? What are approximatively the voltage that can be expected on the
/archives//html/Amps/2006-03/msg00267.html (6,560 bytes)

2. Re: [Amps] Band switching (score: 1)
Author: PA3DUV <pa3duv@planet.nl>
Date: Sat, 11 Mar 2006 15:03:52 +0100
Jos, Check out: http://www.qsl.net/g4ftc/amplifiers/8170/8170_construction/8170_construction.htm This gentleman (g4ftc) has some very interesting pages on construction and engineering considerations
/archives//html/Amps/2006-03/msg00269.html (7,533 bytes)

3. Re: [Amps] Band switching (score: 1)
Author: Peter Chadwick <g3rzp@g3rzp.wanadoo.co.uk>
Date: Sun, 12 Mar 2006 10:38:15 +0100 (CET)
Jos asked: relays or PIN diode ?< The current is a bit high for PINs - it can easily hit 20amps. The voltage rating needs to be at least twice the HV, so we're talking something like 6kV and 20amps f
/archives//html/Amps/2006-03/msg00282.html (7,605 bytes)


This search system is powered by Namazu