1. Re: [Amps] Amps Digest, Vol 96, Issue 48 (score: 1)
Author: "Ron Spencer" <n4vos@bellsouth.net>
Date: Thu, 23 Dec 2010 20:36:22 -0500
Re AL-1500 Plate Meter Circuit Might want to check a diode on the filter cap board its a 1n4007 I had a meter problem on a AL-1200 and the diode was open causing it to have higher readings that norma
/archives//html/Amps/2010-12/msg00329.html (33,195 bytes)

2. Re: [Amps] Amps Digest, Vol 96, Issue 48 (score: 1)
Author: "Jim W7RY" <w7ry@inbox.com>
Date: Thu, 23 Dec 2010 17:59:06 -0800
The diode in this amp on the filter cap board shorted. That caused the grid and plate current meters to read the same. Just the plate current divided on the two meters. Jim W7RY _____________________