- 1. [Amps] Alpha 8100 - R9 meltdown (score: 1)
- Author: David Propper <k2dp@charter.net>
- Date: Thu, 8 Feb 2024 22:02:27 -0600
- Our Alpha 8100 has incurred a failure. Currently have identified that R9 , a 25 ohm, 25 watt ceramic wire wound resistor has overheated and melted some of the ceramic coating. Has anyone seen this fa
- /archives//html/Amps/2024-02/msg00009.html (6,413 bytes)
- 2. Re: [Amps] Alpha 8100 - R9 meltdown (score: 1)
- Author: gudguyham--- via Amps <amps@contesting.com>
- Date: Fri, 9 Feb 2024 11:37:39 +0000 (UTC)
- Thats probably either a step start resistor or a glitch resistor. I would have to look at the schematic. Depending on which it is will depend on the nature of the fault. In either case it could be
- /archives//html/Amps/2024-02/msg00010.html (7,705 bytes)
This search system is powered by
Namazu