- 1. [Amps] Accuracy of Ameritron forward power meter? (score: 1)
- Author: sentek at sprintmail.com (Floyd Sense)
- Date: Sun Mar 16 07:39:25 2003
- Has anyone here checked the accuracy of the forward power meter on the Ameritron amps that share the same power supply board as the AL-80B? (That would include the AL-800, AL-800H, maybe others?) I r
- /archives//html/Amps/2003-03/msg00597.html (7,388 bytes)
- 2. [Amps] Accuracy of Ameritron forward power meter? (score: 1)
- Author: rlcarroll at rcn.com (Robert Carroll)
- Date: Sun Mar 16 09:44:10 2003
- On both my AL80B and AL1500 the Ameritron meter is significantly low on 10m, improving as you go down in bands. I don't think the metering circuit shares the power supply board in the 1500. Bob W2WG
- /archives//html/Amps/2003-03/msg00599.html (8,194 bytes)
- 3. [Amps] Accuracy of Ameritron forward power meter? (score: 1)
- Author: w8ji at contesting.com (Tom Rauch)
- Date: Sun Mar 16 11:30:35 2003
- between Directional couplers always require care to make flat, but the problem is almost never a "shield" between the current transformer secondary and primary. The largest problems are almost alway
- /archives//html/Amps/2003-03/msg00600.html (7,638 bytes)
- 4. [Amps] Accuracy of Ameritron forward power meter? (score: 1)
- Author: sentek at sprintmail.com (Floyd Sense)
- Date: Sun Mar 16 13:13:07 2003
- It was hard to tell what the original hardware stack looked like as a previous owner had apparently tried some misguided fixes. Ameritron supplied me with the Teflon center insulator, an insulated wa
- /archives//html/Amps/2003-03/msg00602.html (9,318 bytes)