1. [Amps] 8877 Warm-Up Period (score: 1)
Author: Byron Tatum <bjtatum1@att.net>
Date: Mon, 23 Jan 2023 22:01:43 +0000 (UTC)
Hello All Fellow Amp Builders-    I agree that it is best to allow the 8877 adaquate warm-up time ahead of the application of high voltage, even when in full cut-off (of course). But equally importan
/archives//html/Amps/2023-01/msg00026.html (7,744 bytes)

2. Re: [Amps] 8877 Warm-Up Period (score: 1)
Author: Jim Barber <barberaudio@gmail.com>
Date: Mon, 23 Jan 2023 14:17:11 -0800
Interesting. I have a HV step-start because if I didn't it would trip the breaker. The xformer is a Dahl 2800V 1A with a 53 uF oil-filled cap and 200K bleeder resistance.The cap is on the large side,
/archives//html/Amps/2023-01/msg00027.html (9,048 bytes)

3. Re: [Amps] 8877 Warm-Up Period (score: 1)
Author: Jim Barber <barberaudio@gmail.com>
Date: Mon, 23 Jan 2023 14:19:48 -0800
Correction: HEATER. Brian may be lurking with his trusty rapier in hand... Jim N7CXI _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/
/archives//html/Amps/2023-01/msg00028.html (9,257 bytes)