- 1. Re: [Amps] 8875 in Dentron MLA 2500B (score: 1)
- Author: "Fortra" <fortra@siol.net>
- Date: Sun, 9 Nov 2014 10:05:05 +0100
- Hi Guys, one of the tubes, 8875 went south in my Dentron MLA 2500B. What is interesting, is that it has occasional contact between pins 5 and 6 when tapping on the body. Measured resistance in good t
- /archives//html/Amps/2014-11/msg00020.html (6,830 bytes)
- 2. Re: [Amps] 8875 in Dentron MLA 2500B (score: 1)
- Author: "N4ZED" <N4ZED@COMCAST.NET>
- Date: Sun, 9 Nov 2014 05:11:36 -0500
- 5 and 6 are the heater. I have had luck with light bulbs when a small break in the filament was "welded" after tapping them with voltage applied. The bulb lasted almost 6 months. Probably worth a try
- /archives//html/Amps/2014-11/msg00021.html (7,874 bytes)
- 3. Re: [Amps] 8875 in Dentron MLA 2500B (score: 1)
- Author: "Carl" <km1h@jeremy.qozzy.com>
- Date: Sun, 9 Nov 2014 09:41:57 -0500
- A single 3CX800 is all the MLA-2500 power transformer can handle and you will increase available dissipation from 600 to 800W. Cooling changes are a little involved but you have a lot of dissipation
- /archives//html/Amps/2014-11/msg00022.html (8,457 bytes)