- 1. [Amps] 3rd Order IMD (score: 1)
- Author: "David C. Hallam" <dhallam@rapidsys.com>
- Date: Wed, 21 Sep 2005 17:45:19 -0400
- Looking through Bill Orr's handbook, I found a table that gives the 3rd order IMD for 6146's in AB1 as about -24/25 db. If that's the case, how can your signal be any cleaner than that as long as the
- /archives//html/Amps/2005-09/msg00273.html (6,554 bytes)
- 2. Re: [Amps] 3rd Order IMD (score: 1)
- Author: "k7fm" <k7fm@teleport.com>
- Date: Wed, 21 Sep 2005 16:20:29 -0700
- The KWM2 uses negative feedback so that the output of the transmitter is cleaner than the 6146 tubes. Collins is excellent in using negative feedback to clean up the signals - which is why the Collin
- /archives//html/Amps/2005-09/msg00277.html (6,973 bytes)
- 3. Re: [Amps] 3rd Order IMD (score: 1)
- Author: R.Measures <r@somis.org>
- Date: Thu, 22 Sep 2005 07:06:14 -0700
- Because 6146 amps typically use RF-NFB, the total IMD is c. 38db from pep. Richard L. Measures, AG6K, 805.386.3734. www.somis.org _______________________________________________ Amps mailing list Amp
- /archives//html/Amps/2005-09/msg00286.html (7,546 bytes)
- 4. Re: [Amps] 3rd Order IMD (score: 1)
- Author: Peter Chadwick <g3rzp@g3rzp.wanadoo.co.uk>
- Date: Thu, 22 Sep 2005 20:03:46 +0200 (CEST)
- Caveat: Well designed 6146 amps use NFB. Not all of them do..... 73 Peter W6/G3RZP (San Diego this week). _______________________________________________ Amps mailing list Amps@contesting.com http://
- /archives//html/Amps/2005-09/msg00293.html (7,425 bytes)
- 5. Re: [Amps] 3rd Order IMD (score: 1)
- Author: "David C. Hallam" <dhallam@rapidsys.com>
- Date: Thu, 22 Sep 2005 14:34:12 -0400
- As much as I believe Hallicrafters and Johnson are well designed transmitters, I don't believe they use NFB in their finals. The equipment at my QTH is exclusively boat anchor. David KC2JD --Original
- /archives//html/Amps/2005-09/msg00295.html (7,772 bytes)
- 6. Re: [Amps] 3rd Order IMD (score: 1)
- Author: R.Measures <r@somis.org>
- Date: Fri, 23 Sep 2005 01:20:10 -0700
- Collins did. Kenwood (TS-820, TS-830) copied Collins. Richard L. Measures, AG6K, 805.386.3734. www.somis.org _______________________________________________ Amps mailing list Amps@contesting.com http
- /archives//html/Amps/2005-09/msg00303.html (7,721 bytes)
- 7. Re: [Amps] 3rd Order IMD (score: 1)
- Author: R.Measures <r@somis.org>
- Date: Fri, 23 Sep 2005 01:27:31 -0700
- Correct, David. Only Collins and Kenwood used RF-NFB, Hallicrafters 6146 SSB transmitters were quite noticably feculent. California is a terrible place to live. Richard L. Measures, AG6K, 805.386.373
- /archives//html/Amps/2005-09/msg00304.html (8,598 bytes)
This search system is powered by