- 1. [Amps] 3 PLATE TRANSFORMERS THAT NEED A NEW HOME. (score: 1)
- Author: ni4l@charter.net (NI4L)
- Date: Mon, 19 Aug 2002 11:54:48 -0400
- This is a nice big plate transformer 14" tall x 11 3/4" wide x 7 1/2" deep 120/220 primaries 3000v @ 3 amps about 100 lbs or close to it. Collins Plate transformer part # 672-1360-00 Pr) 0-105-110-11
- /archives//html/Amps/2002-08/msg00160.html (7,784 bytes)
- 2. [Amps] 3 PLATE TRANSFORMERS THAT NEED A NEW HOME. (score: 1)
- Author: kenw2dtc@comcast.net (kenw2dtc)
- Date: Mon, 19 Aug 2002 15:04:20 -0400
- "GE model 81g465 rated 1.1KVA. 115v in 4620kv@750miliamps center tap." Hi, If the transformer plate tag says 1.1 KVA it's unlikely you could get 750 mills out no matter how you hook it up, do you agr
- /archives//html/Amps/2002-08/msg00162.html (7,375 bytes)
- 3. [Amps] 3 PLATE TRANSFORMERS THAT NEED A NEW HOME. (score: 1)
- Author: drkirkby@ntlworld.com (Dr. David Kirkby)
- Date: Tue, 20 Aug 2002 01:33:20 +0100
- No, at least on a continuous basis. The VA at 750 mA is 4620*0.75=3465 VA, which is a lot more than 1.1 kVA. The subject does say '3 PLATE transformers'. You might just manage if all 3 were used in p
- /archives//html/Amps/2002-08/msg00166.html (7,768 bytes)