- 1. [AMPS] WTB B+ xformer etc (score: 1)
- Author: shane@icu2.net (Shane KI4M/KV4I)
- Date: Mon, 11 Oct 1999 02:52:37 +0100
- I am need of a B+ xformer for an amp that I am considering to purchase. I need a supply that will deliver after the filter caps 3000-4500V @1.2A or so. Would like around 4000V no key. This is for a G
- /archives//html/Amps/1999-10/msg00348.html (7,867 bytes)
- 2. [AMPS] WTB B+ xformer etc (score: 1)
- Author: G3SEK@ifwtech.demon.co.uk (Ian White, G3SEK)
- Date: Mon, 11 Oct 1999 09:06:15 +0100
- You'll see a comfortable 1500W at 3500V on-load, so 4000V off-load and about 3800V key-up (150mA) sounds good. But 100uF is way too much - about 30uF will be plenty. The extra capacitance will only s
- /archives//html/Amps/1999-10/msg00356.html (8,212 bytes)
- 3. [AMPS] WTB B+ xformer etc (score: 1)
- Author: shane@icu2.net (Shane KI4M/KV4I)
- Date: Mon, 11 Oct 1999 11:20:30 +0100
- It would appear that in my hastiness I made a severe typo as well as mental thought on the capacitance and as many of you have pointed out 100uF is indeed to much. I think that I may have found a com
- /archives//html/Amps/1999-10/msg00357.html (8,132 bytes)
- 4. [AMPS] WTB B+ xformer etc (score: 1)
- Author: K1LE@uconect.net (Jeffrey A. Madore)
- Date: Mon, 11 Oct 1999 08:18:57 -0400
- . Also as a dumb question what do most of you use Hi Shane, Standard electrical tape has a low voltage rating, however the rating of a given splice increased with the number of turns. In industrial a
- /archives//html/Amps/1999-10/msg00358.html (8,218 bytes)