1. [AMPS] MHV Connectors (score: 1)
Author: n4kw@citrus.infi.net (Pete Raymond)
Date: Wed, 13 Jun 2001 14:34:07 -0400
Any one using MHV connectors for their High Voltage connectors. None of the catalogs list the voltage/current ratings. Any information would be appreciated. 73 Pete N4KW -- FAQ on WWW: http://www.con
/archives//html/Amps/2001-06/msg00111.html (6,687 bytes)

2. [AMPS] MHV Connectors (score: 1)
Author: Wt8r@aol.com (Wt8r@aol.com)
Date: Wed, 13 Jun 2001 14:44:35 EDT
Pete, According to an Amphenol catalog which I have, the MHV is rated at 5KV, 5 Amps peak, 0-50 MHz. I have used MHV connectors here for a 4KV supply for several years with no problems. As with any o
/archives//html/Amps/2001-06/msg00112.html (7,228 bytes)

3. [AMPS] MHV Connectors (score: 1)
Author: Arne Gjerning" <gjerning@flash.net (Arne Gjerning)
Date: Wed, 13 Jun 2001 16:57:12 -0600
Delta catalog info: DC-50MHz, 3500V RMS, 5000V DC, Dielectric withstanding voltage 5000V RMS, no current rating as such but they are 50 ohm impedance. Suggest looking at MIL-PRF-39012 or MIL-C-3643 f