References: [ +subject:/^(?:^\s*(re|sv|fwd|fw)[\[\]\d]*[:>-]+\s*)*\[AMPS\]\s+Kaput\s+8877s\s+from\s+AL\-1500\s+arrive\s*$/: 4 ]

Total 4 documents matching your query.

1. [AMPS] Kaput 8877s from AL-1500 arrive (score: 1)
Author: 2@vc.net (measures)
Date: Wed, 13 Sep 2000 06:39:00 -0700
AT 5pm yesterday, the duds arrived. I will publish the test results here a.s.a.p. Will Rich be having a crow sandwich for lunch? - Rich..., 805.386.3734, www.vcnet.com/measures. end -- FAQ on WWW: ht
/archives//html/Amps/2000-09/msg00591.html (6,939 bytes)

2. [AMPS] Kaput 8877s from AL-1500 arrive (score: 1)
Author: paulc@mediaone.net (Paul Christensen)
Date: Wed, 13 Sep 2000 09:41:21 -0400
Rich, Can you tell us more about your plan for inspecting these tubes including any methods, procedures, and validation of results? Thanks. -Paul, W9AC -- FAQ on WWW: http://www.contesting.com/FAQ/am
/archives//html/Amps/2000-09/msg00597.html (7,871 bytes)

3. [AMPS] Kaput 8877s from AL-1500 arrive (score: 1)
Author: 2@vc.net (measures)
Date: Wed, 13 Sep 2000 07:51:16 -0700
1. Using a high-pot. set to 8kV, apply negative to the anode and positive to the grid. 2. measure leakage current. 3. reverse polarity. 4. If leakage current remains the same with either polarity, t
/archives//html/Amps/2000-09/msg00601.html (8,370 bytes)

4. [AMPS] Kaput 8877s from AL-1500 arrive (score: 1)
Author: 2@vc.net (measures)
Date: Thu, 14 Sep 2000 14:16:08 -0700
Thr autopsy is finished, Paul. There is minimal loose gold. And why not? 10uA of leakage at +4000v is below normal for a typical gold-sputtered 8877. There are no bare spots where the grid's base me
/archives//html/Amps/2000-09/msg00724.html (10,300 bytes)