1. [AMPS] Hunter Bandit 2000A (score: 1)
Author: Dgb" <dgbcms@bayland.net (Dgb)
Date: Sun, 9 Jan 2000 03:56:04 -0600
I'm in need of the 6 electrolytic, insulated caps used in the power supply filtering of this amp. Their values are 140mf 450v. The factory ones are about 1-3/8" in dia. and 4" long. Anyone have any n
/archives//html/Amps/2000-01/msg00199.html (6,927 bytes)

2. [AMPS] Hunter Bandit 2000A (score: 1)
Author: measures@vcnet.com (measures)
Date: Sun, 9 Jan 2000 05:10:12 -0700
140uF is a bit small for this application. Electrolytic design has advanced. You can now buy more C in the same diameter, in a shorter length. If you want the caps to last, order the 105 degree-C ra