Search String: Display: Description: Sort:

Results:

References: [ +subject:/^(?:^\s*(re|sv|fwd|fw)[\[\]\d]*[:>-]+\s*)*\[AMPS\]\s+Alpah\s+77DX\s+rcve\s+bypass\s+problem\s*$/: 4 ]

Total 4 documents matching your query.

1. [AMPS] Alpah 77DX rcve bypass problem (score: 1)
Author: measures@vc.net (Rich Measures)
Date: Tue, 1 Jun 1999 02:51:48 -0700
- my vote is for residual magnetism, Don. As I recall, there is a reed relay in addition to the vacuum relay. I would interchange the wires leading to the relay coils. - cheers Rich... R. L. Measure
/archives//html/Amps/1999-06/msg00003.html (8,562 bytes)

2. [AMPS] Alpah 77DX rcve bypass problem (score: 1)
Author: philk5pc@tyler.net (Phil Clements)
Date: Tue, 01 Jun 1999 21:13:27 -0700
It is most likely the reed relay contacts sticking on the input side, not the vacuum relay. GL! (((73))) Phil, K5PC -- FAQ on WWW: http://www.contesting.com/ampfaq.html Submissions: amps@contesting.c
/archives//html/Amps/1999-06/msg00017.html (9,260 bytes)

3. [AMPS] Alpah 77DX rcve bypass problem (score: 1)
Author: philk5pc@tyler.net (Phil Clements)
Date: Tue, 01 Jun 1999 21:23:02 -0700
Better yet, since the problem os on receive, jumper around the reed relay contacts with a clip lead after you get the problem initiated with no RX. If the reed relay is stuck, RX will be restored. Yo
/archives//html/Amps/1999-06/msg00018.html (9,718 bytes)

4. [AMPS] Alpah 77DX rcve bypass problem (score: 1)
Author: ve6jy@freenet.edmonton.ab.ca (Don Moman)
Date: Mon, 31 May 1999 16:48:42 -0600 (MDT)
Lost the receive path somewhere in the Alpha 77DX just before the end of the WPX test this past weekend. The direct/aux slide switch has been by-passed so that isn't the problem. Transmit works fine.
/archives//html/Amps/1999-05/msg00348.html (8,197 bytes)


This search system is powered by Namazu