Search String: Display: Description: Sort:

Results:

References: [ +subject:/^(?:^\s*(re|sv|fwd|fw)[\[\]\d]*[:>-]+\s*)*\[AMPS\]\s+3\-500Z\s+101\s*$/: 3 ]

Total 3 documents matching your query.

1. [AMPS] 3-500Z 101 (score: 1)
Author: KF0FX@aol.com (KF0FX@aol.com)
Date: Tue, 16 Jun 1998 09:22:24 EDT
This may seem like a real basic question but keep in mind -- I write software for a living. As I increase the drive to my SB-221 (2x3-500Z), there is a fairly linear relationship between input drive
/archives//html/Amps/1998-06/msg00170.html (7,338 bytes)

2. [AMPS] 3-500Z 101 (score: 1)
Author: jono@webspun.com (Jon Ogden)
Date: Tue, 16 Jun 98 09:09:21 -0500
We will forgive you. :-) It sounds like to me that the amp is being driven into compression too early. Once you've begun to compress the gain significantly, you'll have a nasty signal on the air. Th
/archives//html/Amps/1998-06/msg00171.html (8,832 bytes)

3. [AMPS] 3-500Z 101 (score: 1)
Author: RFpower@radiodan.com (Radiodan W7RF)
Date: Tue, 16 Jun 1998 10:09:23 -0700
Hi Chris, Jon KE9NA said it pretty well. It sounds like you simply have some bad tubes if indeed you do have adequate plate voltage and filament voltage (check input taps on transformer). Be certain
/archives//html/Amps/1998-06/msg00172.html (9,051 bytes)


This search system is powered by Namazu