- 1. [[AMPS] Tetrode poor IMD performance ] (score: 1)
- Author: ac5aa@usa.net (Duane Calvin)
- Date: 15 Aug 2001 22:42:37 CDT
- Expanding a bit on what Paul Christensen wrote - going to the review of 3 amps in QST, Sept 1997, and 4 others in July 1992: Alpha 91b GU-74B/4CX800A AB1 3d/5th ord IMD: 45/49 dB Ameritron 800H 3CX80
- /archives//html/Amps/2001-08/msg00146.html (8,349 bytes)
- 2. [[AMPS] Tetrode poor IMD performance ] (score: 1)
- Author: 2@vc.net (2)
- Date: Wed, 15 Aug 2001 23:37:25 -0700
- // With typical transceiver IMD in the low -30s range, the typical amplifier adds no noticable distortion. cheers, Duane - R. L. Measures, 805.386.3734,AG6K, www.vcnet.com/measures. end -- FAQ on WW
- /archives//html/Amps/2001-08/msg00148.html (9,280 bytes)
- 3. [[AMPS] Tetrode poor IMD performance ] (score: 1)
- Author: Peter.Chadwick@zarlink.com (Peter Chadwick)
- Date: Thu, 16 Aug 2001 07:37:14 +0100
- In the professional field, IMD at -36dB rel PEP from a two tone test has been considered adequate for many years for ISB operation, even with multi channel telegraphy on a sideband where the individu
- /archives//html/Amps/2001-08/msg00149.html (7,216 bytes)
- 4. [[AMPS] Tetrode poor IMD performance ] (score: 1)
- Author: k7fm@teleport.com (Lamb)
- Date: Thu, 16 Aug 2001 15:01:54 -0700
- "It seems a bit doubtful that the 4CX1000A has c. 100-times as much 3rd order distortion as a 4CX1500B" The data I mentioned regarding the 4CX1000 and the 4CX1500 comes from: Care and Feeding of Powe
- /archives//html/Amps/2001-08/msg00165.html (8,849 bytes)
This search system is powered by