- 1. Re: [Amps] article in Nature, modified Aurora via HF (score: 1)
- Author: "MICHAEL FORD" <moo@midmaine.com>
- Date: Tue, 19 Apr 2005 06:48:19 -0400
- A similar effect was used on a daily basis at the Lohnsfeld Germany receiver site. The transmitter was at Ft. Detrick MD and they would come up along side a strong European broadcast station for the
- /archives//html/Amps/2005-04/msg00392.html (7,631 bytes)
- 2. Re: [Amps] Volt-watt meter (score: 1)
- Author: "m.ford" <moo@midmaine.com>
- Date: Fri, 22 Apr 2005 11:48:18 -0400
- Hello Will I recently tested a hv xfmr using banks of 100 watt lamps in series as the load. I measured voltage across one lamp and multiplied by the number of lamps to obtain the total voltage. I fou
- /archives//html/Amps/2005-04/msg00447.html (9,041 bytes)
- 3. Re: [Amps] Shorting Sticks (score: 1)
- Author: "m.ford" <moo@midmaine.com>
- Date: Sun, 24 Apr 2005 17:28:05 -0400
- At my place of employment a young man followed proper procedure by applying the shorting stick to the tank circuit of an S band cross field amplifier before working on the just tested unit. For some
- /archives//html/Amps/2005-04/msg00496.html (7,999 bytes)
- 4. Re: [Amps] Plate transformer current unknown (score: 1)
- Author: "m.ford" <moo@midmaine.com>
- Date: Fri, 29 Apr 2005 14:25:02 -0400
- Just off the top of my bald head I would guess that the current rating would not be all that spectacular due to measured secondary resistance. It seems a bit on the high side. Mike Ford k1ern _______
- /archives//html/Amps/2005-04/msg00621.html (7,682 bytes)
This search system is powered by