Hi Peter
Check TX9 and RX9 supply lines if they are not going to Zero gives problems
with S-meter
my FT1000D did have that problem current runs out of circuit toward Supply (9V)
73 Boye
----- Original Message -----
From: "SM6MCW Peter Andersson" <sm6mcw@skara.net>
To: <yaesu@contesting.com>
Sent: Monday, July 24, 2006 5:58 PM
Subject: [Yaesu] FT1K s-meter
> Hello All,
>
> New to the list and have a question regarding my old FT1000 with
> serialnr: 1C110089
>
> The S-meter have stoppped to work during RX in CW mode, but in SSB mode it
> works when "PROC" is activated. When not, stone dead in SSB also.
> Works OK during TX.
>
> Any help would be good.
>
> Best regards
> Peter Andersson
> SM6MCW es SM6M or SK6M in contest
> _______________________________________________
> Yaesu mailing list
> Yaesu@contesting.com
> http://lists.contesting.com/mailman/listinfo/yaesu
>
>
>
> --
> No virus found in this incoming message.
> Checked by AVG Free Edition.
> Version: 7.1.394 / Virus Database: 268.10.4/396 - Release Date: 24-07-2006
>
>
_______________________________________________
Yaesu mailing list
Yaesu@contesting.com
http://lists.contesting.com/mailman/listinfo/yaesu
|