Hi John,
The larger gauge conductor is for BONDING only. The intent is to
minimize difference in potential between equipment by brute force Ohm's
Law. This is all discussed in the tutorial I referenced, both specific
details of what needs to be bonded and WHY.
For the signal pair, conductors as small as #24 are fine.
73, Jim K9YC
On Mon,12/28/2015 11:13 AM, john@kk9a.com wrote:
I would like to do a better job of interconnecting the many devices in my
shack. Why do you recommend such a heavy and stiff #10 wire? Is smaller
wire or 3/8 braid acceptable?
John KK9A
_______________________________________________
WriteLog mailing list
WriteLog@contesting.com
http://lists.contesting.com/mailman/listinfo/writelog
WriteLog on the web: http://www.writelog.com/
|