Towertalk
[Top] [All Lists]

Re: [TowerTalk] Feedthroughs for rotator cable?

To: towertalk@contesting.com
Subject: Re: [TowerTalk] Feedthroughs for rotator cable?
From: Jim Brown <jim@audiosystemsgroup.com>
Reply-to: jim@audiosystemsgroup.com
Date: Fri, 13 Nov 2020 13:11:39 -0800
List-post: <mailto:towertalk@contesting.com>
On 11/13/2020 12:24 PM, Ross Tucker wrote:
Next question: how do you feed rotator cables through a wall?

I mounted a weatherproof box on the outside of the wall behind the operating desk, brought cable in from the bottom, barrier strips inside the box for SteppIR and rotator control cables, hole drilled in the wall just large enough for 1-in PVC conduit, then cables through the conduit to the operating desk.

The barrier strips have proven quite useful when troubleshooting issues with rodent damage to control cables.

73, Jim K9YC