Towertalk
[Top] [All Lists]

Re: [TowerTalk] Guyed tower question

To: towertalk@contesting.com, nekvtster@gmail.com
Subject: Re: [TowerTalk] Guyed tower question
From: K7LXC@aol.com
Date: Fri, 10 Apr 2009 16:58:52 EDT
List-post: <towertalk@contesting.com">mailto:towertalk@contesting.com>
 
In a message dated 4/10/2009 8:56:46 A.M. Pacific Daylight Time,  
towertalk-request@contesting.com writes:

>  I am putting up 80 ft of Rohn 25. I am using the steel guys  that are 
part of
the extension to the AB577 system. The benefit is they are  one-piece,
adjustable in length and available to me since I'm taking down  my '577 in
favor of the Rohn 25.


>  This is also my first tower installation. I am not  comfortable climbing
above a point that is guyed.


        Then by all means install  it correctly. I doubt that the AB577 
guys are 3/16" EHS as per the factory  specs. Anything less is potentially 
disastrous. 
 
Cheers,
Steve     K7LXC
TOWER TECH -
Professional tower services for hams
**************Feeling the pinch at the grocery store?  Make dinner for $10 
or less. (http://food.aol.com/frugal-feasts?ncid=emlcntusfood00000001)
_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>