What is the length of the run? What cable did you use? What is it not
doing? Can you hear the brake release and does it make noise?
On 10/11/2019 9:20 AM, john@kk9a.com wrote:
Could it be a physical problem? Most Hy-Gain rotator need a shim or a
standard 2" mast and a thicker shim if you're using water pipe. It's
also possible that the brake is sticking or that the motor just does
not have much torque for some reason. Years ago, I had an old TIC ring
rotator motor that seemed to loose it's torque and replacing the motor
(which turned fine with no load) solved the issue.
John KK9A
w5jmw wrote:
Still having problems with my run of rotor cable controlling the rotor.I
have done everything..rotor checks good at ground level.It is now
vertical,changed cables,same thing I am lost now...ideas? 73 john
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
|