DON"T under any circumstances use temporary rope guys when stacking tower 
sections, it can cost you or your climber his life.   

 

Ten months ago, this almost happened to me, while stacking 45G on a pin base.  

 

I am fortunate to be alive and well today, after suffering multiple pelvic and 
back fractures, internal injuries, and vascular damage, when a temporary rope 
guy decided to unexpectedly elongate, and I rode the tower to the ground from 
30 feet.

 

SO....I can't urge you strongly enough, use EHS steel for temporary guying - 
PERIOD  - end of recommendation and strong warning.

 

Yes, EHS is a big pain in the butt to work with, but its SAFE, and that is the 
ONLY WAY to do this dangerous work.  DO NOT TAKE COMPLETELY AVOIDABLE RISKS!

 

Two cents from someone who has been there....and fortunately survived.

 

73,

 

John Crovelli W2GD aka P40W

_________________________________________________________________
Windows Live™: Keep your life in sync.