Towertalk
[Top] [All Lists]

Re: [TowerTalk] Best way to attach radial to radial plate

To: "Dan Bookwalter" <N8DCJ@YAHOO.COM>
Subject: Re: [TowerTalk] Best way to attach radial to radial plate
From: "Mark Robinson" <markrob@mindspring.com>
Date: Sat, 2 Jul 2011 11:45:25 -0400
List-post: <towertalk@contesting.com">mailto:towertalk@contesting.com>
I would crimp and solder the ring terminals. I would also apply some 
Penetrox between the ring terminal and the SS hardware.  I imagine that if a 
lightning strike occurred that the radial wires are more likely to be 
vaporized. The radial field isn't really meant to deal with lightning as it 
is an rf return. Maybe a ground rod and a spark gap would protect a 
vertical. I am not sure how to deal with static on the verticals

I am building their 40m four square right now too, so I will be interested 
in people replies.


Mark N1UK



----- Original Message ----- 
From: "Dan Bookwalter" <n8dcj@yahoo.com>
To: <towertalk@contesting.com>
Sent: Saturday, 02 July, 2011 11:29 AM
Subject: [TowerTalk] Best way to attach radial to radial plate


>I have a DXEngineering radial plate , they suggest using ring terminals , 
>it
> seems to me that if you solder them , if , you taker a lightning strike 
> the
> solder would all be vaporized ? Should I just wrap the wire around the
> screws/bolts and tighten them down that way ?
>
> Dan N8DCJ
>
>
> _______________________________________________
>
>
>
> _______________________________________________
> TowerTalk mailing list
> TowerTalk@contesting.com
> http://lists.contesting.com/mailman/listinfo/towertalk 

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk