I know amateur antennas below 61' are exempt from zoning in
my county, Benton, WA; but don't know about the BUILDING Dept. When I did
my HyGain AV18HT (24' tower with a 24' mast); the Building Dept made me get
a Washington PE licensed in THIS County to do a full-on engineered base
plan, with a wet-stamp; cost well more than the antenna."
One of many reasons I left Washington State for Texas!!! Government run
amuk!!!
Gary J
N5BAA
-----Original Message-----
From: Clay Jackson
Sent: Wednesday, June 4, 2014 11:59 PM
To: TowerTalk@contesting.com
Subject: Re: [TowerTalk] Utility Pole as Beam Support
Thanks to all who replied - tried looking for a BSP on wood poles and
couldn't find the correct index. Any assistance there would be
appreciated.
I'm going to look into some sort of tilt-up "attached pole"; but, failing
that, will just do a rotor/mount and then spend the $$ renting a bucket
truck when I need to do maintenance (tree service will rent me one with an
operator for $75/hour). Main concern on the attached pole would be the
load on the pulley/cable in a wind storm.
Another big consideration will be permitting - need to call the building
dept tomorrow. I know amateur antennas below 61' are exempt from zoning in
my county, Benton, WA; but don't know about the BUILDING Dept. When I did
my HyGain AV18HT (24' tower with a 24' mast); the Building Dept made me get
a Washington PE licensed in THIS County to do a full-on engineered base
plan, with a wet-stamp; cost well more than the antenna.
Any suggestions on the "correct question" would also be appreciated - is it
a "private utility plole" or an "antenna pole" or ??. We're having a big
addition (that required a permit and multiple inspections) and I don't want
to just put it up while there will be inspectors on-site.
73!
Clay
N7QNM
-----Original Message-----
From: Jim W7RY [mailto:w7ry@centurytel.net]
Sent: Tuesday, June 3, 2014 7:31 PM
To: n7qnm-lists@nwlink.com; TowerTalk@contesting.com; n0tt1@juno.com
Subject: Re: [TowerTalk] Utility Pole as Beam Support
BTW, there are Bell System Practices (call BPS's)
BSPs And they are on Google.
73
Jim W7RY
-----Original Message-----
From: n0tt1@juno.com
Sent: Tuesday, June 03, 2014 7:01 PM
To: n7qnm-lists@nwlink.com ; TowerTalk@contesting.com
Subject: Re: [TowerTalk] Utility Pole as Beam Support
Lucky you to get such a pole for free!!! :D)
Use NO concrete! The pole will shrink a little over time and there will be
a crack to let water in and stay there, accelerating the rotting of your
pole! Concrete will also prevent you from making below ground periodic
inspections per the reference suggested below.
Backfill with dirt or use some fine-graded sand that you "water in"
to fill all the voids.
BTW, there are Bell System Practices (call BPS's) that *may* be posted on
the web that describes the proper install, loading, etc of wood poles.
Google. If not, maybe a dedicated Telco ham just might have a copy in his
personal library!
I'd be tempted to rig the beam and mast with a "tilt-over" feature using a
small winch to make it a no-climb antenna structure. A "cradle" would
prevent side-to-side movement at the top.
Now back to my workbench. :D)
73,
Charlie, N0TT
On Tue, 3 Jun 2014 15:15:05 -0700 "Clay Jackson" <n7qnm-lists@nwlink.com>
writes:
I just "inherited" a 50' (out of the ground, 6' buried) utility pole
(crew was taking it out and told me that if I'd drag it off the road,
I could have
it).
I'm thinking about trying to find a rotator and tri-bander to put on
top of it; but, having no experience with such a setup; I thought I'd
seek some advice first.
So, a few questions.
I'm sure someone has done this before; would you be able to share
your experiences?
I have a friend who can weld anything from steel to aluminum and so I
think
we can fab up a mount for the rotor.
Beyond that, thoughts would be appreciated on things like:
Wind loading - how many sq ft (if any) is reasonable before I have to
use guys (for my HyGain AV18HT the building dept made me engineer the
base for 90K winds, WITH a "wet stamped" drawing)?
Base - is a 6' hole filled with dirt "good enough" or do I need
something more (if more, would a 6' hole with concrete be
sufficient)?
Thanks in advance!
Clay
N7QNM
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
-----
No virus found in this message.
Checked by AVG - www.avg.com
Version: 2014.0.4592 / Virus Database: 3955/7622 - Release Date: 06/04/14
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
|