I have had hundreds of feet of hardline of several types and UF Romex
direct burried for many years with no problems.
Chuck W5PR
On Fri, Sep 2, 2016 at 1:28 PM, Jim Brown <jim@audiosystemsgroup.com> wrote:
> On Fri,9/2/2016 10:54 AM, Mitch wrote:
>
>> I'm looking for anyones experience with pulling a long
>> (almost 400ft) length of 7/8" hardline in underground conduit. I have 4"
>> conduit which will have a number of sweeps in it.
>>
>
> That sounds awfully tough to me. WHY does this run need to be in conduit?
> Are you going under a road? FWIW, hard line lives quite well laying on the
> ground as long as you're not driving over it. My neighbor K6XX and I both
> have a lot of 7/8-in laying on the ground, and he has some bigger stuff.
>
> If your reason is to go under a road, can you shorten the section of the
> run that's in conduit by only using conduit to get under the road?
>
> 73, Jim K9YC
>
>
> _______________________________________________
>
>
>
> _______________________________________________
> TowerTalk mailing list
> TowerTalk@contesting.com
> http://lists.contesting.com/mailman/listinfo/towertalk
>
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
|