I pulled a single run on LMR 600 along with a HD rotor cable and control
cable for the Coax Switch through 210 feet of 4". No lube. It came
through just fine. But 200+ feet is a lot of pulling after you have been on
the tower all day.
See https://ki8r.com/tower-project/
On Thu, May 5, 2016 at 12:32 PM, Roger (K8RI) on TT <
K8RI-on-TowerTalk@tm.net> wrote:
> I have 2 runs of LMR600 from the house to the tower and 2 runs from the
> shop to the tower. A total of 4 runs through PVC conduit
> The last photo on http://www.rogerhalstead.com/ham_files/cablebox.htm
> shows the LMR600 from the shop into the junction box on the tower. I used
> a lot of wire pulling lube/soap. I use sweep 45s instead of 90s.
>
> Yes, LMR600 is much more rigid than BuryFlex, but it pulls through 3" PVC
> conduit if there are no sharp bends. Use sweep 45s instead of 90s. LMR600
> is more rigid than LMR400. There is an Ultra Flex version of LMR 400 and
> 600, The LMR400UF is notably more flexible than BuryFlex(TM), BUT the
> jacket is a rubber like material that does not stand up well when exposed
> to the elements. It has a quoted life of 10 years, or half that of
> standard LMR400 and 600s 20 years. I've found the UF versions failed after
> only 5 or 6 years as rotator loops. I had 5 lengths of LMR400UF used as
> rotator loops and leads from the top of the tower to the antennas. The
> jacket on 4 of those actually split while the 5th "looked" to be OK so I
> decided to make jumpers for the station. When installing connectors, I
> found the Al shield and braid to be badly corroded. The jacket had become
> porous and I was seeing water damage. The jacket on the regular LMR 400
> and 600 is tough, but not so for the UF versions.
>
> I used LMR600UF in the conduit to the house to see how well it stands up
> inside of conduit protected from the elements.
>
> 73
>
> Roger (K8RI)
>
>
> On 5/4/2016 Wednesday 8:43 PM, RCM wrote:
>
>> Am I likely to encounter any difficulties pulling LMR-600 through this
>>> conduit? It seems much stiffer than the Buryflex.
>>>
>>> 73,
>>> Jerry
>>> _______________________________________________
>>>
>>> It will go just fine, until the last two feet…. use lube.
>> _______________________________________________
>>
>>
>>
>> _______________________________________________
>> TowerTalk mailing list
>> TowerTalk@contesting.com
>> http://lists.contesting.com/mailman/listinfo/towertalk
>>
>
>
> --
>
> 73
>
> Roger (K8RI)
>
>
> ---
> This email has been checked for viruses by Avast antivirus software.
> https://www.avast.com/antivirus
>
>
> _______________________________________________
>
>
>
> _______________________________________________
> TowerTalk mailing list
> TowerTalk@contesting.com
> http://lists.contesting.com/mailman/listinfo/towertalk
>
--
-----------------------------------------------
*Michael Murphy - KI8R*
mike@ki8r.com
www.ki8r.com
*614-371-8265 (cell)*
-----------------------------------------------
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
|