Mark - I had a situation with a HAM- IV  where I would get BC imod products 
on 160 and 80 . I chased myself all over the place looking for rectifying 
junctions in my antennas. Finally one day I accidentally noticed that if I 
cycled the rotor brake the imod would go away for awhile . A strap of 1/8 
steel cable from the mast to the tower leg took care of that. So now its 
standard procedure for my stuff.