Towertalk
[Top] [All Lists]

Re: [TowerTalk] RE: Tower bolts

To: alwilliams@olywa.net, wtu@cypress.com, towertalk@contesting.com
Subject: Re: [TowerTalk] RE: Tower bolts
From: "Bruce Osterberg" <bruceosterberg@msn.com>
Date: Thu, 30 Sep 2004 18:09:08 -0500
List-post: <mailto:towertalk@contesting.com>
Gentlemen and Ladies:

I just received my bolts today from US tower for a HDX-572 that I will install. They look like regular bolts that are 27 inches long and threaded at both ends. The bottom end has a welded Heavy duty nut on it, (more threads per inch), and the top 6 inches that stick out of the concrete come with three each heavy duty Galvanized nuts. Why three I dont know as the base itself did not arrive just the anchor bolts. The package said 2 of 2 so I suppect it will come tomorrow.

What is interesting is that the Nuts are the heavy duty kind, and galvanized, wereas the anchor rods are not galvanized. The only reason I can think of this is that the rods will be in concrete with 6 inches exposed. and the exposed area under the nuts will be grouted in and the top will have the galvanized bolts. I will still cold Galvanize spray the bolt ends after cleaning them.

Sure hope the base shows up tomorrow!! Winters a coming!



N9BX 73 Bruce




From: "Al Williams" <alwilliams@olywa.net>
To: "Bill Turini" <wtu@cypress.com>, <towertalk@contesting.com>
Subject: Re: [TowerTalk] RE: Tower bolts
Date: Thu, 30 Sep 2004 12:18:11 -0700

I don't know if the UST supplied bolts for the HDX572 are identical or
similar to those used for the TX-472 but if they are;
they are not ordinary straight bolts but rather are in the shape of a J.
The bottom of the J is only 27" overall with only 22" embedded
in the concrete.  The foundation stress analysis claims a Pullout
Capacity = 258,490 pounds and states it is OK.  I can't determine
anything in the tower stress analysis that shows what the pullout stress
is.  Perhaps someone can explain what benefit is obtained by having the
bolts bent into a J  in the concrete.

Also, is the UST supplied stress analysis valid if the J bolts are
replaced with straight bolts?  What effect would that have on a building
permit and an insurance claim if the tower failed?

k7puc

----- Original Message -----
From: "Bill Turini" <wtu@cypress.com>
To: <towertalk@contesting.com>
Sent: Thursday, September 30, 2004 10:53 AM
Subject: [TowerTalk] RE: Tower bolts


> I have a TX-472 tower that I bought used. I called a local bolt firm > that caters to the local maritime and construction trade, told them the > bolt specs and they said "no problem". The first time they charges me > $16 for three bolts (and nuts, washers, and lockwashers). The second > time (8 years later) the price went up to $34 or so, but I had the bolts > made 4' long, with 6" of thread. > > They also supplied ASTM-A36 bolts and nuts for mounting the tower to the > base fixture. Any place that deals with construction that puts up road > signs should be able to help. > > Bill KA4GAV >

_______________________________________________

See: http://www.mscomputer.com for "Self Supporting Towers", "Wireless Weather Stations", and lot's more. Call Toll Free, 1-800-333-9041 with any questions and ask for Sherman, W2FLA.

_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk


_______________________________________________

See: http://www.mscomputer.com for "Self Supporting Towers", "Wireless Weather Stations", and lot's more. Call Toll Free, 1-800-333-9041 with any questions and ask for Sherman, W2FLA.