Mark, The R7 is effectively a 3/8 wavelength vertical, when the loading effects of the trapped elements are considered. The matching network is intended to look at something like 200 ohms. Thus, it will not work with an 18avt, or other quarter wave vertical. N2EA Jim Jarvis, MBA President-Executive Coach The Morse Group, LLC People-Process-Strategy Achieving Results in a Changing World www.themorsegroup.biz _______________________________________________ _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |