The G450XL uses an AC24V motor.
G800/1000 models are DC 24 V.
Not interchangeble.
Dont know if the G450A is the same as G450XL. I cannot find a schematic
of the G450A.
If it uses 3 wires to control your motor it is AC.
2 wires it is DC.
73 Henk PA5KT
Op 11/17/2016 om 14:36 schreef Herbert Schoenbohm:
I have an orphan Yaesu G-8000DXA controller and would like to know if
I can replace by G-450A control box with it without any
modification? The plugs are the same and from the schematic the
control circuit is similar. But I would like to know first before I
brick the rotor on the tower. Please help.
Herb Schoenbohm, KV4FZ