Hey Pete....
That's an interesting finding....   I have come to trust my Autec, but your
findings are far enough at odds with the accepted value for that type of
cable to raise questions...

Can you measure another length of cable without the connectors and report to
us? Or, better yet, couple that with actual power measurements at 10 meters
on the existing cable (with connectors) comparing input and output...  I have
a couple of drums of the stuff but none rolled out at the moment that I can
do a quick measurement on...

Denny

--