Towertalk
[Top] [All Lists]

[TowerTalk] Low Loss Coax

To: <towertalk@contesting.com>
Subject: [TowerTalk] Low Loss Coax
From: K7LXC@aol.com (K7LXC@aol.com)
Date: Wed, 9 Jan 2002 10:33:58 EST
In a message dated 1/9/02 5:47:42 AM Pacific Standard Time, 
george.shaw@ukf.net writes:

> What is the minimum static bending radius on coax. Very few give that
>  detail. 

    It's typically six times the diameter so the minimum bending radius for 
1/2" coax would be three inches. I probably wouldn't stress foam-filled coax 
that much due to the potential for foam cold-flow problems. 

>  And how do you deal with an installation of say LM-600 that has to
>  go horizontally then vertically (from the 12th floor apartment to the roof 
@
>  15th floor)? Is it OK to fit a 90 degree connector? 

    Sure. But if you can put something under it to protect it from the sharp 
edge as it crosses the edge of the roof, then you don't really need the 90 
degree connector.

>  What sort of loss would there be? I have hear mention of 1.5db per 
connector?

    It's not that much. Andrew, the Heliax people, use 0.2 dB per connector 
in their loss calcs. According to some guys on TT it's even less than that.

Cheers,
Steve    K7LXC
Tower Tech 

________________________________________________________________________
This list is sponsored by the new eHam.net Store.  When you buy products
like ICE filters, Array Solutions StackMatch, or M-Squared Antennas from
the eHam Store for the same price you pay direct, a portion of the sale
price goes to support this list.  Check it out at http://www.eham.net.

-----
FAQ on WWW:               http://www.contesting.com/FAQ/towertalk
Submissions:              towertalk@contesting.com
Administrative requests:  towertalk-REQUEST@contesting.com
Problems:                 owner-towertalk@contesting.com


<Prev in Thread] Current Thread [Next in Thread>