| "For the interested student", here's a treatise on leakage and other 
losses in power (60 Hz) transformers that might be of use: 
https://tinyurl.com/2te6xhkv . 
73 de
Gene Smar  AD3F
On 11/21/2021 2:11 PM, Michael Tope wrote:
 
Hi Jim,
Starting with version 5.0, EZNEC implements the capability to model 
lumped transformers, inductors, capacitors, and resistors. Thus, it 
should have capability to model the Collins 90deg hybrid. The only 
caveat is that the transformer model is ideal (K=1.0), so including 
the impact of flux leakage and core loss would have to be captured 
with additional components in an equivalent circuit model. 
73,  Mike W4EF............
 