| One more alternative is to use a DX Eng saddle clamp and extend the 
saddle backing plate far enough to use two hole lugs.  I made the 
backing plate out of 1/4 x 1-1/2" 6061 and wide enough for two lugs each 
side.  One clamp on each leg with 2 or 3  #6 or #2 wires to pairs of 
buried 8' rods Cadwelded.  I put some contact goop in the saddle area 
where it contacts the tower.  2" saddles for Rohn 65 are a very close 
fit.  A few dollars cheaper than the Rohn similar idea, and uses two 
hole lugs.  Aluminum against zinc is pretty benign electrochemically. 
Grant KZ1W
On 10/16/2017 11:58 AM, Jim Brown wrote:
 
On 10/15/2017 7:35 PM, Ward Silver wrote:
 Use a proper clamp designed to connect copper wire to galvanized 
tower legs.  For Rohn 25, the clamp is part number R/CPC-1.25
 
Here are two sources with what seem to be the best prices. If you poke 
deeper, you learn that the two links are simply different DBAs for the 
same business. :)  $30 each. 
https://www.cableandwireshop.com/rohn-tower-grounding.html
https://www.3starinc.com/rohn_r-cpc11_25_tower_base_ground_clamp.html
I just ordered clamps to replace the stainless steel hose clamps that 
I'm currently using. The website let me place an order without adding 
yet another password. :) 
73, Jim K9YC