To: | towertalk@contesting.com |
---|---|
Subject: | Re: [TowerTalk] Tower grounding connections and foundation |
From: | Patrick Greenlee <patrick_g@windstream.net> |
Date: | Sat, 8 Aug 2015 12:51:58 -0500 |
List-post: | <towertalk@contesting.com">mailto:towertalk@contesting.com> |
On 8/8/2015 12:32 PM, JVarney wrote: Since it is the surface area that is key in the wording why not a wide thin copper strap. Not in a reductio ad absurdum manner but similar to the copper foil straps/tapes used commonly for RF grounding.Also, I misquoted TIA-222-G: #00 is not specifically required, it says connections between tower and rods shall be "not smaller in surface area than 2/0 solid." I interpret that to mean that the spec could be met with multiple strands of #4 or #6 in parallel. Patrick NJ5G _______________________________________________ _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: [TowerTalk] Tower grounding connections and foundation, JVarney |
---|---|
Next by Date: | Re: [TowerTalk] Tower grounding connections and foundation, Thomas Noel |
Previous by Thread: | Re: [TowerTalk] Tower grounding connections and foundation, JVarney |
Next by Thread: | Re: [TowerTalk] Tower grounding connections and foundation, Thomas Noel |
Indexes: | [Date] [Thread] [Top] [All Lists] |