Why not an RF choke for static drain/noise purposes across a spark gap for
direct hit purposes ?
Gene / W2LU
----- Original Message -----
From: "Jim Lux" <jimlux@earthlink.net>
To: <towertalk@contesting.com>
Sent: Saturday, February 09, 2013 7:18 PM
Subject: Re: [TowerTalk] grounding elevated vertical for lightning?
On 2/9/13 12:43 PM, Mark Robinson wrote:
Could he not also ground through an rf choke to bleed off static?
At first that's what I thought, but OP was looking for lightning
protection.
And, if you wanted to operate top band, for instance, a choke that has
high Z at 2MHz is also going to have high Z for lightning (which has a lot
of its power around 1 MHz). Even for 80m, it would be tricky..