On 12/9/2013 8:29 AM, Jorge Diez - CX6VM wrote:
Thanks to all for the answers, interesting feedback!, thanks!

Seems I will do it as actually, underground.

Cables will not be direct buried, will go through a plastic pipe, so I don´t
think that would have considerably more capacitance to ground.

Actually I´m afraid I will find some water or humidity inside the pipe and
along the cables. Will need to improve that, with a deeper channel, drainage
and a gentle slope to allow water does not stay inside the pipe.
'
It gets rained on outside. Avoid connections in the conduit. If you can't avoid then, just thoroughly waterproof them. I don't even have drains in my conduit. and it's going on 10 years. The only concern I have about water in the conduit is freezing this time of year. What's there is there to stay, and I doubt I could add more. OTOH, all I need to do is set up a heat gun (on low) or hair dryer (on high)blowing into the conduit from the basement and let run for a few hours to dry it out. All you need is high volume, "warm" air. You may get a lot of condensation at the tower end.

73

Roger (K8RI)



Lighting is something to improve. A project for next year, very expensive
since I have more than 18 cables (coaxial and control lines) going to the
shack. It´s obvious that will need a Polyphaser sponsorship at CW5W :-)

Thanks!

Jorge
CX6VM/CW5W

-----Mensaje original-----
De: TowerTalk [mailto:towertalk-bounces@contesting.com] En nombre de David
Robbins
Enviado el: lunes, 09 de diciembre de 2013 10:58 a.m.
Para: towertalk@contesting.com
Asunto: Re: [TowerTalk] from towers to shack


Consider a direct strike to the tower? The cables being above or
below ground don't materially change the voltage waveform, at least
as selection of the suppression devices are concerned: it's kilovolts
you need to deal with.
Cables "tapped" to the tower are coming off a voltage gradient from
several
hundred KV at the top of the tower
to zero at ground (if the tower is properly grounded).  At 10 feet on a
100
foot tower, one had several 10s of KV ..
not easily dealt with using simple devices.
But of course ground is not 'zero' once the current traveling down the tower
gets to it, the ground potential rises also.  What you need to protect
against are the signal/power carrying conductors having a different
potential than the shields of the coax or ground where the equipment is.

Conventional transient suppression techniques work for phone and
power lines, which run above ground for miles.
Phone and power lines are not connected to lightning rods several times
the
height of the lines.

Most distribution lines are at the TOP of the poles and get hit directly,
phone lines are usually 3/4's of the way or more up the poles... and even
more important they are not coaxial lines so the power carrying conductor is
hit which takes it directly into transformers, switches, and other
equipment.
Important Note, it is not the voltage handling capability of arresters that
matter, when the arrester turns on from a stroke it limits the voltage
across itself, that is what its purpose is!  It is the current or integrated
energy handling capability of the arresting device that is important.  How
you can help it is by keeping all the grounds bonded together, this keeps
the potential difference between the protected cable and the local ground
smaller which reduces the amount of current that the arrester must pass to
equalize the potential between the signal/power lead and ground.

David Robbins K1TTT
e-mail: mailto:k1ttt@arrl.net
web: http://wiki.k1ttt.net
AR-Cluster node: 145.69MHz or telnet://k1ttt.net

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk


_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>