Make sure you transition to EHS at the bottom for security/vandalism.
Philly will burn so if there is any chance of a grass fire around your
tower you will want to keep the Philly off the ground and the area
around the guy points mowed down.
Mike W0MU
W0MU-1 CC Cluster w0mu.net:23 or w0mu-1.dnsdynamic.com
Http://www.w0mu.com
On 8/20/2012 10:32 AM, john@kk9a.com wrote:
> All of my Phillystran cables connect directly to the tower brackets with
> either Big Grips or Spelter Sockets. You can use a shackle for easy
> removal if you wish. For the connection between Phillystran and EHS, I
> just use back to back thimbles.
>
> BTW, if you have a tower twisting issue, star guying is much more
> effective than torque arms.
>
> John KK9A
>
>
> To: towertalk@contesting.com
> Subject: [TowerTalk] Phillystran Guys
> From: Tom Harke <tom@tomharke.com>
> Date: Mon, 20 Aug 2012 10:17:43 -0500
>
> I am in the process of preparing the guys for my latest tower project. I
>
> am looking for recommendations on attaching the Phillystran guys to the
> tower torque arms. I can shackle the guy directly to the torque arm or
> use a approx 5-6 feet of 1/4" EHS with Big Grips attached to the torque
> arms and then shackle to Philly to the 1/4" EHS.
> I would appreciate any input on which would be the best way to do this.
>
> Thanks
>
> Tom AA9A
>
>
> _______________________________________________
>
>
>
> _______________________________________________
> TowerTalk mailing list
> TowerTalk@contesting.com
> http://lists.contesting.com/mailman/listinfo/towertalk