On 5/21/2010 5:34 PM, Richard (Rick) Karlquist wrote:
> Let me greatly simplify this discussion.
>
> Get a TWO port network analyzer and connect
> the DUT from the center conductor of port 1
> to the center conductor of port 2. Measure
> S22 and calculate the impedance of the DUT.
> This eliminates most of the well known gotcha's
> associated with measuring high impedances.
> You should be able to measure even 50,000
> ohms with no trouble.
>
> If you just want to know the magnitude of the
> impedance, you can fake a network analyzer
> by using a signal generator and a receiver.
> Just measure insertion loss of the balun.
>
> Only works for floating DUT's but that includes
> baluns. It also doesn't matter much if the
> terminals are far apart physically.
>
> Rick N6RK
>
>
I think you meant to type "S21", Rick.
73, Mike W4EF.........................