bob finger wrote:
> Amen!! . Bending and twisting Rohn 25 trying to put enough tension on
> the guys can ruin a good day. 73 bob de w9ge
>
> Cqtestk4xs@aol.com wrote:
>
>> You do not need the heavy duty stuff!!!!! DO NOT use it. You can not
>> tension it to the proper tension as it will be pulling way too hard on the
>> Rohn
>> 25 tower.
>>
Nothing says you have to tension the cable to a particular fraction of
it's breaking strength. It's more a matter of the desired tension for
appropriate stability for the structure. You could tension million
pound breaking strength cable to the same few hundred pounds as the the
regular non-EHS cable.
Now, if the cable is particularly heavy (per unit length) compared to
the design cable, there are some issues, but I wouldn't think that's the
case here, comparing EHS and regular cables.