| jimlux wrote: > clad steel. Aluminum is about 60% the conductivity of copper, so > considering it as a "tube", if you go 60% bigger diameter, you'll have The 60% is at DC. At RF is it the square root of 0.6, which is something like 78%. This is due to the curious phenomenon that the skin depth is thicker in the aluminum, which partially makes up for the lower conductivity. Rick N6RK _______________________________________________ _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk | 