Purchased a TX-472MDP, which included the MDP-750, an RMC-1000 Remote Control,
a MCL-100 Limit Switch Control in September 1998. Up until the last few days,
the US Towers equipment has operated flawlessly.
Prior to a monsoon hitting the area (Chino Valley, AZ), used the RMC-1000 to
lower the tower, and the fuse blew in the Remote Control box. Discovered a
couple of problems, 1) the DOWN relay (Omron G7J-4A-B) is defective and am
waiting for replacement and 2) ground wire between the Relay box on the tower
and the RMC-1000 is disconnected, the fuse stops blowing.
Disconnecting ground in the RMC-1000 and leaving ground wire attached in Relay
Box, fuses continues to blow. Disconnected the cable between RMC-1000 and
Relay Box and attached the RMC-1000 to Relay Box at the tower. Fuse still
blows when ground wire is connected.
The Relay Box mounted on the tower and the RMC-1000 Remote Control boxes are
very simple, however, US Towers does not have schematics.
1st. Any one have schematic I can have (purchase).
2nd. Has anyone have experienced the blowing of the RMC-1000 fuse and when
disconnecting the wire in the Relay Box (only) the fuse does not blow. Cable,
between Relay Box and RMC-1000 checks out A-OK - - - no short or high
resistance short between any of the wires
Dick Diddams W7QHE
_______________________________________________
See: http://www.mscomputer.com for "Self Supporting Towers", "Wireless Weather
Stations", and lot's more. Call Toll Free, 1-800-333-9041 with any questions
and ask for Sherman, W2FLA.