Towertalk
[Top] [All Lists]

[TowerTalk] MFJ-259B and Distance to Fault

To: <towertalk@contesting.com>
Subject: [TowerTalk] MFJ-259B and Distance to Fault
From: ditzian@alltel.net (ditzian@alltel.net)
Date: Tue, 4 Dec 2001 11:42:23 -0500
I have an MFJ-259B and I want to use it to measure Distance-to-
Fault.  I tried this, following the directions, and the coax in question 
showed that there was a fault at a distance far greater than the 
length of the coax, even after multiplying by Vf = .66.

I then tried shorting out the end of the coax (center to braid), but I 
still read a distance to fault greater than the length of the coax.  
This distance is different from the one without the short.  
Furthermore, at different frequencies (that show an X crossing 0) I 
get different results, all distances greater than the length of the 
coax, with and without the short.

Is a short at the end of the coax not equivalent to a fault?


73,
Jan Ditzian
KX2A
kx2a@arrl.net


List Sponsored by AN Wireless:  AN Wireless handles Rohn tower systems,
Trylon Titan towers, coax, hardline and more. Also check out our self
supporting towers up to 100 feet for under $1500!!  http://www.anwireless.com

-----
FAQ on WWW:               http://www.contesting.com/FAQ/towertalk
Submissions:              towertalk@contesting.com
Administrative requests:  towertalk-REQUEST@contesting.com
Problems:                 owner-towertalk@contesting.com