Hi:
I currently have a 59' foot 25 tower with the guy anchors 55' away from
the base. I'd like to take the tower to 90' so I can stack a total of 3
F12 C3's at 30', 60' and 90'.
However, Rohn calls for 80% spacing from the base which would be 72' so
I'm 17' shy of the needed distance. I'm in a position where I cannot
move my anchors back any further as the tower sits on a roof.
Knowing the first directive (do what the manufacture says) should I
scrap this idea or is there a chance to make this work? If I get real
serious, I'll be best served to get an engineer involved I'm sure.
Sure would be nice to have a 3 stack. You can see pictures of the
current tower at the web site below my signature.
--
73,
Richard Thorne
ARS N5ZC (ex KA2DSY, N2BHP, WB5M)
Remote Control Airplanes: AMA# 657062
http://www.tcac.net/~rthorne/
--
FAQ on WWW: http://www.contesting.com/towertalkfaq.html
Submissions: towertalk@contesting.com
Administrative requests: towertalk-REQUEST@contesting.com
Problems: owner-towertalk@contesting.com