I am putting up 100 feet of Rohn 55 and have a guy wire question. My
preference is to use Phyllistrand nonconductive guys and I have no experience
with this product having always used 3/16 inch steel.
My question is which size of the Phyllistrand to use. I believe there are
four different sizes of Phyllistrand available. The PHTG21001 has a breaking
strength of 2100 pounds and the HPTG 40001 is rated at 4000 pounds.
The 3/16 inch EHS is rated around 3900 pounds and I have never had a failure
with this particular guy cable size.
Would the 2100 pound Phyllistrand work OK? Any recommendations would be
appreciated. Thanks.
Tom
K4XG