Thanks, everyone. Looks like all I have are vaporized traces, so I'm
ready to reinstall the Stackmatch.
73, Pete N4ZR
At 08:49 PM 6/3/2009, Kevin C. Kidd CSRE/AMD wrote:
>MOV's should fail shorted or destroyed. A visual or simple continuity
>check will locate those. Occasionally they will fail open. There is a
>HV tester for MOV's but if you have access to a megger or hipot tester
>that will work as well.
>
>Otherwise just replace them all. They are cheap and very effective...
>
>john@kk9a.com wrote:
> > WX0B relays are pretty tough, I have had many direct lightning strikes and
> > no relay damage - even with no MOV protection near the relay.
> >
> > I have had MOV's short after a direct hit, so sometimes they fail
> closed. I
> > always replaced any that were obviously burnt even if open.
> >
> > John KK9A
> >
> >
>--
>Kevin C. Kidd, CSRE/AMD
>WD4RAT
>mailto:kkidd@kkbc.com
>
>KK BROADCAST ENGINEERING
>http://www.kkbc.com
>
>AM GROUND SYSTEMS CO.
>http://www.amgroundsystems.com
>
>51 Ridge Ln
>Lawrenceburg, TN 38464
>Local: 931-766-2999
>Nation Wide: 877-766-2999
>FAX: 931-766-3974
>_______________________________________________
>
>
>
>_______________________________________________
>TowerTalk mailing list
>TowerTalk@contesting.com
>http://lists.contesting.com/mailman/listinfo/towertalk
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
|