To: | "towertalk@contesting.com" <towertalk@contesting.com> |
---|---|
Subject: | Re: [TowerTalk] Tower grounding cable...??? |
From: | "Jim Brown" <jim@audiosystemsgroup.com> |
Date: | Tue, 02 Dec 2008 22:52:42 -0800 |
List-post: | <towertalk@contesting.com">mailto:towertalk@contesting.com> |
On Tue, 2 Dec 2008 21:22:42 -0800 (PST), Michael Germino wrote: >Should the bolts for the tower be bonded to the structural steel in >the concrete base? why are we viewing the bolts as different from the tower or the tower base? Electrically they must all be bonded together! Yes, the tower base should be bonded to the structural steel in the concrete base, and to the earth electrode system. Yes, we need to avoid dissimilar metal issues. 73, Jim K9YC _______________________________________________ _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: [TowerTalk] Crank down towers when away, Roger (K8RI) |
---|---|
Next by Date: | [TowerTalk] grounding, Allan Greening |
Previous by Thread: | Re: [TowerTalk] Tower grounding cable...???, Michael Germino |
Next by Thread: | Re: [TowerTalk] Tower grounding cable...???, Michael Germino |