Towertalk
[Top] [All Lists]

Ground Rod Placement

To: <towertalk@contesting.com>
Subject: Ground Rod Placement
From: k7fr@ncw.net (Gary Nieborsky)
Date: Tue, 29 Oct 1996 08:37:48 -0800
Roger,

National Electric Code Article 800, Section C , specifically 810-51
addresses amateur installation.  It states that your tower must be bonded to
your house ground system.  In an interpretations book I have it references
that the NEC is assuming the typical ham installation with the
tower/mast/pole located immediately adjacent to the structure.  What they
are trying to avoid is the possibility of someone touching the
tower/mast/pole and a grounded device at the same time and getting the
begabbers shocked out of them.  Lightning factors into it too.  It also
addresses conductor size etc.  A most fascinating section to read.

I've copied the reflector for general interest.

73 Gary K7FR

At 10:32 PM 10/28/96 +0000, you wrote:
>Hi Guys,
>
>Can anyone tell me if there is any electrical code that specifies how far
>from the side of my house I should bury an 8-ft. ground rod? 
>
>I have a 9-ft. peaked roof mounted tower and I will be running a very heavy
>gauge (thick as my thumb) jacketed stranded copper cable from the tower leg
>to the ground rod. 
>
>If there is no code for this application, are there any recommendations?
>
>Roger, K2JAS 
>
>
>--
>FAQ on WWW:               http://www.contesting.com/towertalkfaq.html
>Submissions:              towertalk@contesting.com
>Administrative requests:  towertalk-REQUEST@contesting.com
>Problems:                 K7LXC@contesting.com
>Sponsored by Akorn Access, Inc & KM9P
>
>


--
FAQ on WWW:               http://www.contesting.com/towertalkfaq.html
Submissions:              towertalk@contesting.com
Administrative requests:  towertalk-REQUEST@contesting.com
Problems:                 K7LXC@contesting.com
Sponsored by Akorn Access, Inc & KM9P